Horizontal 'Z' Flashings
Quickflash Code 20, Code 21, Code 22, Code 27, Code 28, Code 29
Code 20 - (12mm cladding)
Horizontal 'Z' Flashings are made in 3.0m lengths
A | 52mm |
B | 13mm |
C | 35mm |
D | 10mm |
Code 21 - (20mm cladding)
Horizontal 'Z' Flashings are made in 3.0m lengths
A | 54mm |
B | 21mm |
C | 35mm |
D | 10mm |
Code 22 - (40mm cladding)
Horizontal 'Z' Flashings are made in 3.0m lengths
A | 64mm |
B | 41mm |
C | 35mm |
D | 10mm |
Code 27 - (06mm cladding)
Horizontal 'Z' Flashings are made in 3.0m lengths
A | 61mm |
B | 7mm |
C | 35mm |
D | 7mm |
Code 28 - (7.5mm cladding)
Horizontal 'Z' Flashings are made in 3.0m lengths
A | 60mm |
B | 8mm |
C | 35mm |
D | 7mm |
Code 29 - (10mm cladding)
Horizontal 'Z' Flashings are made in 3.0m lengths
A | 57mm |
B | 11mm |
C | 35mm |
D | 7mm |
Available In
*Solid Plaster & Aluminium should not come in contact
Galvanised Steel
Aluminium
Colorsteel Maxx
Stainless Steel
Specifications:
- Galvanised Steel - Z450 - 0.55mm
- Aluminium - 5000 Series - 0.7mm
- Colorsteel Maxx - Thunder Grey - 0.55mm
- Stainless Steel - 304 - 0.5mm
Refer to E2/AS1 - Tables 20, 21 & 22
Product Details
The Horizontal 'Z' Flashings waterproof the horizontal joint between cladding junctions while forming a clean straight line to the cladding below.
They must lap over the cladding below and under the cladding above by 35mm minimum.
Downloads
- quickflash_code_20.pdf
- quickflash_code_21.pdf
- quickflash_code_22.pdf
- quickflash_code_27.pdf
- quickflash_code_28.pdf
- quickflash_code_29.pdf
DXF
- quickflash_code_20.dxf
- quickflash_code_21.dxf
- quickflash_code_22.dxf
- quickflash_code_27.dxf
- quickflash_code_28.dxf
- quickflash_code_29.dxf
DWG
- quickflash_code_20.dwg
- quickflash_code_21.dwg
- quickflash_code_22.dwg
- quickflash_code_27.dwg
- quickflash_code_28.dwg
- quickflash_code_29.dwg
RFA
- quickflash_code_20.rfa
- quickflash_code_21.rfa
- quickflash_code_22.rfa
- quickflash_code_27.rfa
- quickflash_code_28.rfa
- quickflash_code_29.rfa